Follow
Kiarash Gharani Khajeh
Title
Cited by
Cited by
Year
Redundant observability PMU placement in the presence of flow measurements considering contingencies
M Esmaili, K Gharani, HA Shayanfar
IEEE Transactions on Power Systems 28 (4), 3765-3773, 2013
1162013
Integrated model considering effects of zero injection buses and conventional measurements on optimal PMU placement
KG Khajeh, E Bashar, AM Rad, GB Gharehpetian
IEEE Transactions on Smart Grid 8 (2), 1006-1013, 2015
1152015
A novel filter design method for grid-tied inverters
D Solatialkaran, KG Khajeh, F Zare
IEEE Transactions on Power Electronics 36 (5), 5473-5485, 2020
322020
Harmonic analysis of multi-parallel grid-connected inverters in distribution networks: Emission and immunity issues in the frequency range of 0-150 khz
KG Khajeh, D Solatialkaran, F Zare, N Mithulananthan
IEEE Access 8, 56379-56402, 2020
302020
Harmonic analysis of grid-tied active front end inverters for the frequency range of 0-9 kHz in distribution networks: Addressing future regulations
H Rathnayake, KG Khajeh, F Zare, R Sharma
2019 IEEE International Conference on Industrial Technology (ICIT), 446-451, 2019
222019
Harmonic analysis of grid‐connected inverters considering external distortions: addressing harmonic emissions up to 9 kHz
K Gharani Khajeh, D Solatialkaran, F Zare, N Mithulananthan
IET Power Electronics 13 (10), 1934-1945, 2020
162020
A full-feedforward technique to mitigate the grid distortion effect on parallel grid-tied inverters
KG Khajeh, F Farajizadeh, D Solatialkaran, F Zare, J Yaghoobi, ...
IEEE Transactions on Power Electronics 37 (7), 8404-8419, 2022
152022
Output filter design for grid-tied cascaded multi-level inverters based on novel mathematical expressions
D Solatialkaran, KG Khajeh, F Zare
IEEE Access 8, 62505-62516, 2020
152020
A harmonic mitigation technique for multi-parallel grid-connected inverters in distribution networks
KG Khajeh, D Solatialkaran, F Zare, F Farajizadeh, J Yaghoobi, ...
IEEE Transactions on Power Delivery 37 (4), 2843-2856, 2021
132021
An enhanced full‐feedforward strategy to mitigate output current harmonics in grid‐tied inverters
K Gharani Khajeh, D Solatialkaran, F Zare, N Mithulananthan
IET Generation, Transmission & Distribution 15 (5), 827-835, 2021
62021
Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies
M Esmaili, HA Shayanfar, K Gharani
Iranian Journal of Electrical and Electronic Engineering 10 (4), 283-292, 2014
52014
Harmonic Cancellations in Parallel Active Front End Inverters in Distribution Networks: IEC 61000-3-16 and Phase-Angles
F Zare, J Yaghoobi, K Gharani, D Kumar
2020 19th International Conference on Harmonics and Quality of Power (ICHQP …, 2020
32020
A full-feedforward harmonic mitigation scheme in multi-parallel grid-tied inverters
KG Khajeh, D Solatialkaran, F Zare, M Nadarajah
2020 IEEE International Conference on Power Electronics, Drives and Energy …, 2020
22020
Harmonic investigation and mitigation of multiple grid-tied inverters with LCL filter
K Gharani Khajeh
2022
The system can't perform the operation now. Try again later.
Articles 1–14