Follow
Dionysios Bournas
Dionysios Bournas
Senior Researcher, European Laboratory for Structural Assessment, Safety and Security of Buildings
Verified email at ec.europa.eu - Homepage
Title
Cited by
Cited by
Year
Strengthening of concrete structures with textile reinforced mortars: State-of-the-art review
LN Koutas, Z Tetta, DA Bournas, TC Triantafillou
Journal of Composites for Construction 23 (1), 03118001, 2019
3962019
Textile-reinforced mortar versus fiber-reinforced polymer confinement in reinforced concrete columns
DA Bournas, PV Lontou, CG Papanicolaou, TC Triantafillou
ACI Structural Journal 104 (6), 740, 2007
3602007
Textile-reinforced mortar (TRM) versus fiber-reinforced polymers (FRP) in shear strengthening of concrete beams
ZC Tetta, LN Koutas, DA Bournas
Composites Part B: Engineering 77, 338-348, 2015
2842015
Performance of industrial buildings during the Emilia earthquakes in Northern Italy and recommendations for their strengthening
DA Bournas, P Negro, FF Taucer
Bulletin of Earthquake Engineering 12, 2383-2404, 2014
2422014
Textile-reinforced mortar (TRM) versus fibre-reinforced polymers (FRP) in flexural strengthening of RC beams
SM Raoof, LN Koutas, DA Bournas
Construction and Building Materials 151, 279-291, 2017
2042017
TRM vs FRP jacketing in shear strengthening of concrete members subjected to high temperatures
ZC Tetta, DA Bournas
Composites Part B: Engineering 106, 190-205, 2016
1642016
Textile-reinforced mortar versus FRP jacketing in seismic retrofitting of RC columns with continuous or lap-spliced deformed bars
DA Bournas, TC Triantafillou, K Zygouris, F Stavropoulos
Journal of Composites for Construction 13 (5), 360-371, 2009
1602009
Flexural strengthening of RC columns with NSM FRP or stainless steel
DA Bournas, TC Triantafillou
Aci Struct. J 106 (4), 495-505, 2009
1442009
TRM versus FRP in flexural strengthening of RC beams: Behaviour at high temperatures
SM Raoof, DA Bournas
Construction and building materials 154, 424-437, 2017
1422017
Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms
DA Bournas, P Negro, FJ Molina
Engineering structures 57, 609-627, 2013
1412013
Energy performance of existing residential buildings in Europe: A novel approach combining energy with seismic retrofitting
DA Pohoryles, C Maduta, DA Bournas, LA Kouris
Energy and buildings 223, 110024, 2020
1382020
Bond between TRM versus FRP composites and concrete at high temperatures
SM Raoof, DA Bournas
Composites Part B: Engineering 127, 150-165, 2017
1372017
Bond between textile-reinforced mortar (TRM) and concrete substrates: Experimental investigation
SM Raoof, LN Koutas, DA Bournas
Composites Part B: Engineering 98, 350-361, 2016
1362016
Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites combined with insulation materials: A new concept
DA Bournas
Composites Part B: Engineering 148, 166-179, 2018
1352018
Shear strengthening of full-scale RC T-beams using textile-reinforced mortar and textile-based anchors
ZC Tetta, LN Koutas, DA Bournas
Composites Part B: Engineering 95, 225-239, 2016
1352016
Pseudodynamic tests on a full-scale 3-storey precast concrete building: global response
P Negro, DA Bournas, FJ Molina
Engineering structures 57, 594-608, 2013
1232013
Experimental assessment of the seismic performance of a prefabricated concrete structural wall system
A Pavese, DA Bournas
Engineering Structures 33 (6), 2049-2062, 2011
1182011
Out-of-plane response of masonry walls strengthened using textile-mortar system
FA Kariou, SP Triantafyllou, DA Bournas, LN Koutas
Construction and Building Materials 165, 769-781, 2018
1062018
Flexural strengthening of two-way RC slabs with textile-reinforced mortar: experimental investigation and design equations
LN Koutas, DA Bournas
Journal of Composites for Construction 21 (1), 04016065, 2017
1062017
Out-of-plane strengthening of masonry-infilled RC frames with textile-reinforced mortar jackets
LN Koutas, DA Bournas
Journal of Composites for Construction 23 (1), 04018079, 2019
1022019
The system can't perform the operation now. Try again later.
Articles 1–20