Follow
Simone Pezzuto
Title
Cited by
Cited by
Year
Active stress vs. active strain in mechanobiology: constitutive issues
D Ambrosi, S Pezzuto
Journal of Elasticity 107, 199-212, 2012
1622012
Verification of cardiac mechanics software: benchmark problems and solutions for testing active and passive material behaviour
S Land, V Gurev, S Arens, CM Augustin, L Baron, R Blake, C Bradley, ...
Proceedings of the Royal Society A: Mathematical, Physical and Engineering …, 2015
1182015
Solid tumors are poroelastic solids with a chemo-mechanical feedback on growth
D Ambrosi, S Pezzuto, D Riccobelli, T Stylianopoulos, P Ciarletta
Journal of Elasticity 129, 107-124, 2017
662017
Epicardial fibrosis explains increased endo–epicardial dissociation and epicardial breakthroughs in human atrial fibrillation
A Gharaviri, E Bidar, M Potse, S Zeemering, S Verheule, S Pezzuto, ...
Frontiers in physiology 11, 68, 2020
562020
An orthotropic active–strain model for the myocardium mechanics and its numerical approximation
S Pezzuto, D Ambrosi, A Quarteroni
European Journal of Mechanics-A/Solids 48, 83-96, 2014
562014
Fast uncertainty quantification of activation sequences in patient‐specific cardiac electrophysiology meeting clinical time constraints
A Quaglino, S Pezzuto, PS Koutsourelakis, A Auricchio, R Krause
International journal for numerical methods in biomedical engineering 34 (7 …, 2018
472018
Space‐discretization error analysis and stabilization schemes for conduction velocity in cardiac electrophysiology
S Pezzuto, J Hake, J Sundnes
International journal for numerical methods in biomedical engineering 32 (10 …, 2016
462016
Evaluation of a rapid anisotropic model for ECG simulation
S Pezzuto, P Kal'avskż, M Potse, FW Prinzen, A Auricchio, R Krause
Frontiers in physiology 8, 246472, 2017
432017
Reconstruction of three-dimensional biventricular activation based on the 12-lead electrocardiogram via patient-specific modelling
S Pezzuto, FW Prinzen, M Potse, F Maffessanti, F Regoli, ML Caputo, ...
EP Europace 23 (4), 640-647, 2021
412021
High-order finite element methods for cardiac monodomain simulations
KP Vincent, MJ Gonzales, AK Gillette, S Pezzuto, AD McCulloch
Frontiers in physiology 6, 147935, 2015
352015
Active contraction of the cardiac ventricle and distortion of the microstructural architecture
S Pezzuto, D Ambrosi
International journal for numerical methods in biomedical engineering 30 (12 …, 2014
242014
Physics-informed neural networks to learn cardiac fiber orientation from multiple electroanatomical maps
C Ruiz Herrera, T Grandits, G Plank, P Perdikaris, F Sahli Costabal, ...
Engineering with Computers 38 (5), 3957-3973, 2022
232022
Activation models for the numerical simulation of cardiac electromechanical interactions
R Ruiz-Baier, D Ambrosi, S Pezzuto, S Rossi, A Quarteroni
Computer Models in Biomechanics: From nano to macro, 189-201, 2013
182013
Learning atrial fiber orientations and conductivity tensors from intracardiac maps using physics-informed neural networks
T Grandits, S Pezzuto, FS Costabal, P Perdikaris, T Pock, G Plank, ...
International Conference on Functional Imaging and Modeling of the Heart …, 2021
172021
PIEMAP: personalized inverse eikonal model from cardiac electro-anatomical maps
T Grandits, S Pezzuto, JM Lubrecht, T Pock, G Plank, R Krause
International Workshop on Statistical Atlases and Computational Models of …, 2020
172020
Short P‐wave duration is a marker of higher rate of atrial fibrillation recurrences after pulmonary vein isolation: new insights into the pathophysiological mechanisms through …
A Auricchio, T Özkartal, F Salghetti, L Neumann, S Pezzuto, A Gharaviri, ...
Journal of the American Heart Association 10 (2), e018572, 2021
162021
The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients
F Maffessanti, T Jadczyk, R Kurzelowski, F Regoli, ML Caputo, G Conte, ...
EP Europace 22 (5), 777-786, 2020
142020
High-dimensional and higher-order multifidelity Monte Carlo estimators
A Quaglino, S Pezzuto, R Krause
Journal of Computational Physics 388, 300-315, 2019
142019
Beat-to-beat P-wave morphological variability in patients with paroxysmal atrial fibrillation: an in silico study
S Pezzuto, A Gharaviri, U Schotten, M Potse, G Conte, ML Caputo, ...
EP Europace 20 (suppl_3), iii26-iii35, 2018
132018
Impact of mechanical deformation on pseudo-ECG: a simulation study
M Favino, S Pozzi, S Pezzuto, FW Prinzen, A Auricchio, R Krause
EP Europace 18 (suppl_4), iv77-iv84, 2016
132016
The system can't perform the operation now. Try again later.
Articles 1–20