Follow
Dr. Patrick Schuenke
Dr. Patrick Schuenke
Verified email at ptb.de
Title
Cited by
Cited by
Year
Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CEST MRI data
P Schuenke, J Windschuh, V Roeloffs, ME Ladd, P Bachert, M Zaiss
Magnetic resonance in medicine 77 (2), 571-580, 2017
1532017
A combined analytical solution for chemical exchange saturation transfer and semi‐solid magnetization transfer
M Zaiss, Z Zu, J Xu, P Schuenke, DF Gochberg, JC Gore, ME Ladd, ...
NMR in Biomedicine 28 (2), 217-230, 2015
1282015
Assessing the predictability of IDH mutation and MGMT methylation status in glioma patients using relaxation-compensated multipool CEST MRI at 7.0 T
D Paech, J Windschuh, J Oberhollenzer, C Dreher, F Sahm, JE Meissner, ...
Neuro-oncology 20 (12), 1661-1671, 2018
1122018
Adiabatically prepared spin‐lock approach for T1ρ‐based dynamic glucose enhanced MRI at ultrahigh fields
P Schuenke, C Koehler, A Korzowski, J Windschuh, P Bachert, ME Ladd, ...
Magnetic resonance in medicine 78 (1), 215-225, 2017
972017
T1ρ-weighted dynamic glucose-enhanced MR imaging in the human brain
D Paech, P Schuenke, C Koehler, J Windschuh, S Mundiyanapurath, ...
Radiology 285 (3), 914-922, 2017
922017
Fast and quantitative T1ρ-weighted dynamic glucose enhanced MRI
P Schuenke, D Paech, C Koehler, J Windschuh, P Bachert, ME Ladd, ...
Scientific reports 7 (1), 42093, 2017
752017
Pulseq‐CEST: Towards multi‐site multi‐vendor compatibility and reproducibility of CEST experiments using an open‐source sequence standard
K Herz, S Mueller, O Perlman, M Zaitsev, L Knutsson, PZ Sun, J Zhou, ...
Magnetic resonance in medicine 86 (4), 1845-1858, 2021
252021
On the energy response function of a CdTe Medipix2 Hexa detector
T Koenig, A Zwerger, M Zuber, P Schuenke, S Nill, E Guni, A Fauler, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2011
252011
A novel normalization for amide proton transfer CEST MRI to correct for fat signal–induced artifacts: application to human breast cancer imaging
F Zimmermann, A Korzowski, J Breitling, JE Meissner, P Schuenke, L Loi, ...
Magnetic resonance in medicine 83 (3), 920-934, 2020
242020
Chemical exchange saturation transfer (CEST) signal intensity at 7T MRI of WHO IV° gliomas is dependent on the anatomic location
C Dreher, J Oberhollenzer, JE Meissner, J Windschuh, P Schuenke, ...
Journal of Magnetic Resonance Imaging 49 (3), 777-785, 2019
232019
Dual‐frequency irradiation CEST‐MRI of endogenous bulk mobile proteins
S Goerke, J Breitling, M Zaiss, J Windschuh, P Kunz, P Schuenke, ...
NMR in Biomedicine 31 (6), e3920, 2018
222018
High Exchange Rate Complexes of 129Xe with Water‐Soluble Pillar[5]arenes for Adjustable Magnetization Transfer MRI
M Schnurr, R Joseph, A Naugolny‐Keisar, D Kaizerman‐Kane, ...
ChemPhysChem 20 (2), 246-251, 2019
212019
Dynamic glucose‐enhanced (DGE) MRI in the human brain at 7 T with reduced motion‐induced artifacts based on quantitative R mapping
PS Boyd, J Breitling, F Zimmermann, A Korzowski, M Zaiss, P Schuenke, ...
Magnetic resonance in medicine 84 (1), 182-191, 2020
142020
A comparison of various strategies to equalize the lower energy thresholds of a CdTe medipix2 hexa detector for x-ray imaging applications
T Koenig, M Zuber, A Zwerger, P Schuenke, S Nill, A Fauler, M Fiederle, ...
Journal of Instrumentation 6 (01), C01074, 2011
112011
Steady-state CEST-MRI using a reduced saturation period
J Breitling, S Goerke, JE Meissner, A Korzowski, P Schuenke, ME Ladd, ...
MR-based protein imaging of the human brain by means of dualCEST, 99, 2018
62018
An NMR relaxometry approach for quantitative investigation of the transchelation of gadolinium ions from GBCAs to a competing macromolecular chelator
P Werner, M Taupitz, L Schröder, P Schuenke
Scientific Reports 11 (1), 21731, 2021
52021
Investigating the Role of Sulfate Groups for the Binding of Gd3+ Ions to Glycosaminoglycans with NMR Relaxometry
P Werner, P Schuenke, O Krylova, H Nikolenko, M Taupitz, L Schröder
ChemMedChem 17 (13), e202100764, 2022
32022
Fat corrected APT-CEST in the human breast
F Zimmermann, A Korzowski, P Schuenke, J Breitling, M Zaiss, D Paech, ...
22018
Rapid analytical CEST spectroscopy of competitive host–guest interactions using spatial parallelization with a combined approach of variable flip angle, keyhole and averaging …
HA Morik, P Schuenke, L Schröder
Physical Chemistry Chemical Physics 24 (20), 12126-12135, 2022
12022
Simultaneous mapping of B 0, B 1 and T 1 for the correction of CEST-MRI
K Heinecke, H Narvaez, C Kolbitsch, P Schuenke
ISMRM & SMRT Annual Meeting & Exhibition, 15-20, 2021
12021
The system can't perform the operation now. Try again later.
Articles 1–20