Follow
Dr. Patrick Schuenke
Dr. Patrick Schuenke
Verified email at ptb.de
Title
Cited by
Cited by
Year
Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CEST MRI data
P Schuenke, J Windschuh, V Roeloffs, ME Ladd, P Bachert, M Zaiss
Magnetic resonance in medicine 77 (2), 571-580, 2017
1812017
A combined analytical solution for chemical exchange saturation transfer and semi‐solid magnetization transfer
M Zaiss, Z Zu, J Xu, P Schuenke, DF Gochberg, JC Gore, ME Ladd, ...
NMR in biomedicine 28 (2), 217-230, 2015
1552015
Assessing the predictability of IDH mutation and MGMT methylation status in glioma patients using relaxation-compensated multipool CEST MRI at 7.0 T
D Paech, J Windschuh, J Oberhollenzer, C Dreher, F Sahm, JE Meissner, ...
Neuro-oncology 20 (12), 1661-1671, 2018
1472018
T1ρ-weighted dynamic glucose-enhanced MR imaging in the human brain
D Paech, P Schuenke, C Koehler, J Windschuh, S Mundiyanapurath, ...
Radiology 285 (3), 914-922, 2017
1062017
Adiabatically prepared spin‐lock approach for T1ρ‐based dynamic glucose enhanced MRI at ultrahigh fields
P Schuenke, C Koehler, A Korzowski, J Windschuh, P Bachert, ME Ladd, ...
Magnetic resonance in medicine 78 (1), 215-225, 2017
1052017
Fast and quantitative T1ρ-weighted dynamic glucose enhanced MRI
P Schuenke, D Paech, C Koehler, J Windschuh, P Bachert, ME Ladd, ...
Scientific reports 7 (1), 42093, 2017
832017
Pulseq‐CEST: towards multi‐site multi‐vendor compatibility and reproducibility of CEST experiments using an open‐source sequence standard
K Herz, S Mueller, O Perlman, M Zaitsev, L Knutsson, PZ Sun, J Zhou, ...
Magnetic resonance in medicine 86 (4), 1845-1858, 2021
472021
A novel normalization for amide proton transfer CEST MRI to correct for fat signal–induced artifacts: application to human breast cancer imaging
F Zimmermann, A Korzowski, J Breitling, JE Meissner, P Schuenke, L Loi, ...
Magnetic resonance in medicine 83 (3), 920-934, 2020
382020
Chemical exchange saturation transfer (CEST) signal intensity at 7T MRI of WHO IV° gliomas is dependent on the anatomic location
C Dreher, J Oberhollenzer, JE Meissner, J Windschuh, P Schuenke, ...
Journal of Magnetic Resonance Imaging 49 (3), 777-785, 2019
252019
High Exchange Rate Complexes of 129Xe with Water‐Soluble Pillar[5]arenes for Adjustable Magnetization Transfer MRI
M Schnurr, R Joseph, A Naugolny‐Keisar, D Kaizerman‐Kane, ...
ChemPhysChem 20 (2), 246-251, 2019
242019
On the energy response function of a CdTe Medipix2 Hexa detector
T Koenig, A Zwerger, M Zuber, P Schuenke, S Nill, E Guni, A Fauler, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2011
242011
Dual‐frequency irradiation CEST‐MRI of endogenous bulk mobile proteins
S Goerke, J Breitling, M Zaiss, J Windschuh, P Kunz, P Schuenke, ...
NMR in Biomedicine 31 (6), e3920, 2018
232018
Dynamic glucose‐enhanced (DGE) MRI in the human brain at 7 T with reduced motion‐induced artifacts based on quantitative R mapping
PS Boyd, J Breitling, F Zimmermann, A Korzowski, M Zaiss, P Schuenke, ...
Magnetic resonance in medicine 84 (1), 182-191, 2020
152020
An NMR relaxometry approach for quantitative investigation of the transchelation of gadolinium ions from GBCAs to a competing macromolecular chelator
P Werner, M Taupitz, L Schröder, P Schuenke
Scientific Reports 11 (1), 21731, 2021
132021
A comparison of various strategies to equalize the lower energy thresholds of a CdTe medipix2 hexa detector for x-ray imaging applications
T Koenig, M Zuber, A Zwerger, P Schuenke, S Nill, A Fauler, M Fiederle, ...
Journal of Instrumentation 6 (01), C01074, 2011
92011
Steady-state CEST-MRI using a reduced saturation period
J Breitling, S Goerke, JE Meissner, A Korzowski, P Schuenke, ME Ladd, ...
MR-based protein imaging of the human brain by means of dualCEST, 99, 2018
72018
PINQI: an end-to-end physics-informed approach to learned quantitative MRI reconstruction
FF Zimmermann, C Kolbitsch, P Schuenke, A Kofler
IEEE Transactions on Computational Imaging, 2024
42024
Investigating the Role of Sulfate Groups for the Binding of Gd3+ Ions to Glycosaminoglycans with NMR Relaxometry
P Werner, P Schuenke, O Krylova, H Nikolenko, M Taupitz, L Schröder
ChemMedChem 17 (13), e202100764, 2022
42022
Fast WASABI post-processing: Access to rapid B0 and B1 correction in clinical routine for CEST MRI
C Papageorgakis, E Firippi, B Gy, T Boutelier, I Khormi, O Al-Iedani, ...
Magnetic resonance imaging 102, 203-211, 2023
32023
Validate your CEST simulation!
P Schuenke, K Herz, Z Zu, N Yadav, Q Zheng, M Huemer, R Stollberger, ...
32023
The system can't perform the operation now. Try again later.
Articles 1–20