Follow
Claudia Prieto
Title
Cited by
Cited by
Year
Whole‐heart coronary MR angiography with 2D self‐navigated image reconstruction
M Henningsson, P Koken, C Stehning, R Razavi, C Prieto, RM Botnar
Magnetic resonance in medicine 67 (2), 437-445, 2012
2412012
Highly efficient respiratory motion compensated free‐breathing coronary MRA using golden‐step Cartesian acquisition
C Prieto, M Doneva, M Usman, M Henningsson, G Greil, T Schaeffter, ...
Journal of magnetic resonance imaging 41 (3), 738-746, 2015
2392015
Motion corrected compressed sensing for free‐breathing dynamic cardiac MRI
M Usman, D Atkinson, F Odille, C Kolbitsch, G Vaillant, T Schaeffter, ...
Magnetic resonance in medicine 70 (2), 504-516, 2013
2312013
CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions
T Küstner, N Fuin, K Hammernik, A Bustin, H Qi, R Hajhosseiny, PG Masci, ...
Scientific reports 10 (1), 13710, 2020
2072020
Highly efficient nonrigid motion‐corrected 3D whole‐heart coronary vessel wall imaging
G Cruz, D Atkinson, M Henningsson, RM Botnar, C Prieto
Magnetic resonance in medicine 77 (5), 1894-1908, 2017
1512017
Five‐minute whole‐heart coronary MRA with sub‐millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D‐PROST reconstruction
A Bustin, G Ginami, G Cruz, T Correia, TF Ismail, I Rashid, R Neji, ...
Magnetic resonance in medicine 81 (1), 102-115, 2019
1412019
High‐dimensionality undersampled patch‐based reconstruction (HD‐PROST) for accelerated multi‐contrast MRI
A Bustin, G Lima da Cruz, O Jaubert, K Lopez, RM Botnar, C Prieto
Magnetic resonance in medicine 81 (6), 3705-3719, 2019
1372019
From compressed-sensing to artificial intelligence-based cardiac MRI reconstruction
A Bustin, N Fuin, RM Botnar, C Prieto
Frontiers in cardiovascular medicine 7, 501814, 2020
1322020
Automatic CNN-based detection of cardiac MR motion artefacts using k-space data augmentation and curriculum learning
I Oksuz, B Ruijsink, E Puyol-Antón, JR Clough, G Cruz, A Bustin, C Prieto, ...
Medical image analysis 55, 136-147, 2019
1202019
Accelerated motion corrected three‐dimensional abdominal MRI using total variation regularized SENSE reconstruction
G Cruz, D Atkinson, C Buerger, T Schaeffter, C Prieto
Magnetic resonance in medicine 75 (4), 1484-1498, 2016
1182016
k‐t group sparse: a method for accelerating dynamic MRI
M Usman, C Prieto, T Schaeffter, PG Batchelor
Magnetic Resonance in Medicine 66 (4), 1163-1176, 2011
1102011
Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory
M Usman, B Ruijsink, MS Nazir, G Cruz, C Prieto
Magnetic resonance imaging 38, 129-137, 2017
842017
Nonrigid motion modeling of the liver from 3-D undersampled self-gated golden-radial phase encoded MRI
C Buerger, RE Clough, AP King, T Schaeffter, C Prieto
IEEE transactions on medical imaging 31 (3), 805-815, 2012
842012
Sparsity and locally low rank regularization for MR fingerprinting
G Lima da Cruz, A Bustin, O Jaubert, T Schneider, RM Botnar, C Prieto
Magnetic resonance in medicine 81 (6), 3530-3543, 2019
802019
Multi‐parametric liver tissue characterization using MR fingerprinting: Simultaneous T1, T2, T2*, and fat fraction mapping
O Jaubert, C Arrieta, G Cruz, A Bustin, T Schneider, G Georgiopoulos, ...
Magnetic resonance in medicine 84 (5), 2625-2635, 2020
792020
Deep learning-based detection and correction of cardiac MR motion artefacts during reconstruction for high-quality segmentation
I Oksuz, JR Clough, B Ruijsink, EP Anton, A Bustin, G Cruz, C Prieto, ...
IEEE Transactions on Medical Imaging 39 (12), 4001-4010, 2020
782020
Water–fat Dixon cardiac magnetic resonance fingerprinting
O Jaubert, G Cruz, A Bustin, T Schneider, B Lavin, P Koken, ...
Magnetic resonance in medicine 83 (6), 2107-2123, 2020
772020
A survey on deep learning and explainability for automatic report generation from medical images
P Messina, P Pino, D Parra, A Soto, C Besa, S Uribe, M Andía, C Tejos, ...
ACM Computing Surveys (CSUR) 54 (10s), 1-40, 2022
752022
3D undersampled golden‐radial phase encoding for DCE‐MRA using inherently regularized iterative SENSE
C Prieto, S Uribe, R Razavi, D Atkinson, T Schaeffter
Magnetic resonance in medicine 64 (2), 514-526, 2010
732010
3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST
A Bustin, I Rashid, G Cruz, R Hajhosseiny, T Correia, R Neji, R Rajani, ...
Journal of Cardiovascular Magnetic Resonance 22 (1), 24, 2020
692020
The system can't perform the operation now. Try again later.
Articles 1–20